The Gold Standard for High-Output 15 GPM Maintenance
Is your LUMINOR controller beeping or flashing a lamp replacement alert? High-output systems require precise UV-C dosages to maintain safety at 15 GPM flow rates. The LUMINOR RL-420HO is the only authorized replacement designed to work with the specialized high-frequency ballasts found in LBH4, LBH5, and LBH6-15X series, as well as the following High-Output Rack configurations:
- LBH4 Series: LBH4-Z2, LBH4-Z12, LBH4-Z22, LBH4-Z122, LBH4-Z222
- LBH5 Series: LBH5-Z2, LBH5-Z12, LBH5-Z22, LBH5-Z122, LBH5-Z222
Why Genuine LUMINOR Lightlock™ & LPHO Tech Matters
- LPHO Advantage: Unlike standard lamps, the RL-420HO (Blue Base) is a Low-Pressure, High-Output bulb. It provides nearly double the UV-C output of a standard lamp within the same 16.5″ footprint.
- Electronic Handshake: The included key tells your controller exactly which lamp is installed, ensuring the power supply delivers the precise 45W wattage required for optimal intensity.
- Safety Compliance: Using non-genuine lamps can lead to “ballast stress,” overheating, or “under-dosing,” which leaves your water unprotected and voids your manufacturer’s warranty.
Technical Specifications
| Feature | Details |
|---|---|
| Model Number | RL-420HO |
| Compatible Systems | LBH4/5/6-15X, LBH4-Z & LBH5-Z Series Rack Systems |
| Replacement Sleeve | RQ-420 (Sold Separately) |
| Lamp Length | 16.5″ (420mm) |
| Wattage | 45 Watts |
| Base Color | Blue |
| Expected Life | 10,000 Hours (Approx. 14 Months) |
| Warranty | 1-Year No-Hassle Replacement |
How to Replace Your RL-420HO Lamp (Video Tutorial Below)
Replacing the lamp is a dry process. There is no need to drain the system.
Step 1. Obtain the correct lamp as shown on the silver label of the reactor or the maintenance parts screen.
Step 2. If a by-pass assembly is installed, shut the inlet valve off to prevent water flow through the system. Otherwise, turn off main water inlet valve (and/or turn off the water pump)
Step 3. Unplug the power for the controller. For 51/6.1 systems, remove and discard the Lamp Key from the controller
Step 4. Unscrew the captive ground screw from the ground lug on the UV reactor.
Step 5. Push down lamp cable and turn 1/4 turn counterclockwise to release lamp cable from gland nut.
Step 6. Disconnect and remove the old lamp from the chamber.
Step 7. The replacement lamp is packaged with a lamp key on the connector at the end of the lamp. Remove the key from the lame and place it in the controller.
Step 8. Remove the lamp from its packaging, always holding the lamp by its ceramic ends (the use of cotton gloves is recommended).
Step 9. Insert the UV lamp into the reactor, being careful not to drop it.
Step 10. Plug the LUMI-loc lamp connector into the lamp, note the keying for proper alignment. Insert the lamp connector into the gland nut and turn the connector approximately 1/4 turn to lock.
Step 11. Tighten the captive ground screw to the ground lug on the UV reactor to ensure proper grounding.
Step 12. For 4.1 systems, reset the timer in the controller by holding down the button on the controller for 10 seconds.