Complete Maintenance Kit (RLQ-820)
-
RL-820 UV Lamp: Delivers consistent 254nm UV-C intensity for a full 9,000 hours (1 year). Includes the proprietary internal coating to prevent the “output drop” common in generic bulbs.
-
RQ-820 Pure Quartz Sleeve: Made from premium GE214 quartz, this sleeve provides 99.9% clarity. Its fire-polished ends and 34.1″ length are specifically engineered for the 101-series reactor chamber to prevent stress fractures and leaks.
What’s in the Box?
- (1) RL-820 UV Lamp (39 Watts)
- (1) RQ-820 Quartz Sleeve (GE214 Quartz)
- (1) Lightlock™ Electronic Replacement Key
- (2) Replacement O-Rings for a leak-proof seal
Technical Specifications
Compatible Systems: BLACKCOMB LB4-101, LB5-101, LB6-101
Lamp Length: 32.3″ (820mm)
Sleeve Length: 34.1″ (866mm)
Lamp Wattage: 39W
Service Life: 12 Months (9,000 Hours)
Certification: Protects NSF/UL system certifications and manufacturer warranty.
Pro-Installer Maintenance Tip It’s recommended to wear cotton gloves when handling the new RL-820 lamp and RQ-820 sleeve. Oils from your skin can create “hot spots” on the glass, which may lead to premature failure or clouding. If the glass is touched, wipe it down with a clean cloth and isopropyl alcohol before sliding it into the reactor.




Reviews